Fire Alarm Systems
12
![]() | Zeta Alarm Systems Detector Common BaseThere are 4 types of base suitable for use on an addressable system, a common base, a relay base, a sounder base, or a short circuit protection isolator base |
![]() | Zeta Alarm Systems Duct unitThe Fyreye duct unit enables monitoring of an air duct for smoke particles. It is available with a standard base or a relay base. It is supplied with ductsampling probes |
![]() | EVERDAY Conventional DetectorsEverday's line of 2 and 4 wire conventional detectors is carefully designed to reduce installation, maintenance, operating costs and improved in performance. All conventional detectors have international approvals such as EN-54, UL, ULC, CE |
![]() | LIFECO CONVENTIONAL DetectorsThe Photoelectric detector was designed based on theory in which the light emits diffusively to various directions when reflecting onto the smoke cell. 12 to 32 VDC Range |
![]() | IMAKE SD-98-4 4 wire Smoke Detector* LED indicator, No polarized, 4-wire * Network by relay, N.O/N.C Optional * Input Voltage: 10-35VDC * Standby Current:≦15mA * Alarm Current:≦15mA * Alarm output: Relay output (N.O/N.C) and LED flash * Auto-reset function, Excellent smoke access * With detector base |
![]() | Zeta Alarm Systems Conventional Beam DetectorThe 2 wire Fyreye beam detector can be run from the detection zone of a Premier SX or Premier M Plus panel without the need for a separate PSU.A 4 wire version is available for other panels which can not support zone powered operation. These require a separate 24V power supply |
![]() | Zeta Alarm Systems Conventional manual callpointsZeta call points (also known as break glass unit - BGU) are available as glass or resettable. They have a perspex cover to prevent accidental operation, and an LED to indicate operation. They have a test point to check for normal operation. Available also in weatherproof and explosion proof housings |
![]() | Zeta Alarm Systems Conventional Remote IndicatorsRemote LED indicators are used when detectors are fitted behind doors which are likely to be locked. They will show the location of a detector inalarm without having to open the door. It is available with steady or flashing twin LEDs |
![]() | Zeta Alarm Systems Miditone sounders / FlashersThe miditone sounder and flasher range are designed to fit a 1 gang box. They come supplied with a back box for surface mounting. Output 98 dB at 1 m |
![]() | Zeta Alarm Systems Securetone SoundersThe Securetone Range is the latest sounder design from Zeta Alarms. They are designed for fitting with no visible screw fixings. Output 102 dB at 1 m |
![]() | Zeta Alarm Systems Industrial SoundersINDUSTRIAL MEGATONE SOUNDERS & FLASHERSThese are high output sounders designed for use in places with high background noise. They have a 120 dB output at 1m |
![]() | Zeta Alarm Systems Maxitone soundersMAXITONE sounders and flashers are the standard sounders supplied by Zeta alarms. They have a large backbox with multiple cable knockouts to enable clutter free installation. Output 104 dB at 1 m |
![]() | IMAKE IM-86 Strobe Siren* Voltage: 24VDC * Current: 100mA * Color: RED COLOR * Power: 112db/30cm * Temperature: -10℃ to 50℃ * New caving-in type harmonic bell sound |
![]() | Zeta Alarm Systems Flame proof SoundersThe Zeta flame proof siren is an explosion proof siren available in either 24V or 230V versions. An intrinsically safe circuit is housed in the main chamber and it is duly wired up to terminal chamber |
![]() | Zeta Alarm Systems Analogue Fixed Temperature Linear Heat Detection SystemThe combination of LDM92198/F control module and TC9208/F heat tracer cable can adapt to a variety of environmental conditions due to built in “self adapting compensation”. This compensation assures |
![]() | VESDA Very Early Warning Aspirating Smoke DetectionVESDA by Xtralis very early warning aspirating smoke detection solutions with continuous air sampling provide the earliest possible warning of an impending fire hazard. VESDA ASDs buy the critical time needed to investigate an alarm and initiate an appropriate response to prevent injury, property damage or business disruption. VESDA detectors have multi-level warnings and a wide range of sensitivity that does not degrade or change over time, so even minute levels of smoke can be detected before a fire has time to escalate. In addition, VESDA systems are manufactured using targeted Six Sigma techniques and ISO 9000 standards and have been certified by regulatory bodies worldwide |
![]() | Zeta Alarm Systems LASD Aspirated Smoke Detection System For Laser Smoke DetectorsThe LASD1 and LASD2 aspiration systems actively draw air from the protected area through a network of 25mm pipes perforated with sampling holes. The system incorporates one or two Laser point smoke detectors, allowing for redundancy or mixed detection strategies. Each model utilises a high performance aspirator and fl ow monitoring circuitry, with the flow level indicated on a bar graph. |
![]() | Zeta Alarm Systems LAZ-R Firetracer High Sensitivity Laser Aspirated Smoke Detection SystemThe Zeta LAZ-R range of detectors provide the earliest possible warning to any potential fi re threat. They can detect smoke down to levels of 0.001% They are ideal for many applications, including power stations, telecom centres, IT facilities, LCD fab`s, semi conductor clean rooms, logistic centres, cold storage, prisons, historic buildings, museums, mines and other harsh and hazardous areas. The LAZ-R aspiration system is available in 1,4,6,8 or 15 |
![]() | Zeta Alarm Systems Fireresistant cablesFire Defence Cable is manufactured in the UK using the latest technology and materials. Materials and processes are recorded and tracked throughout manufacture to ensure consistent reliability and quality, all cables are marked with time & date of manufacture. Fire defence cable has been independently tested and approved by LPB to meet with BS5839-1:2002, BS8434-1:2003 . Also available CAT5 fire resistant cable and Coaxial fire resistant cable |
12